Inclinometer System for Dump Trucks Trailer Tip-over Monitoring ZCT-CX05-RC01

Product Short Description

Enquiry

Description

Parameter

How To Order

Download

I. General Description

ZCT-CX05-RC01 inclinometer system is designed and produced by ZC Tech, the measuring range is ±20 degree, and made of sensor and display. It is with zero set, alarm angle set function, and the built-in clock chip realize the system log function which can be set and read by the connection PC and USB interface. It can be used as safety monitoring record for construction machines.

P/N ZC-CX05-RC01
Axis Single axis
Accuracy 0.2°
Resolution 0.1°
Power supply DC8~36Vol
Total range +-15° Optioal
Output 485 and with readout,external port for valve
IP Grade IP67

 

II. Features   

Entirely industrial device;
Stable and reliable performance;
Automatically log function;
Wide power supply and power reversion protection.

 

III. Application

Engineering vehicle inclination measure and record;
Aerial lifts safety monitoring;
Dump truck.

 

IV. Technical Specification

Parameter

Test condition

Min.

Typ.

Max.

Unit

Operation parameter

Power supply

8

24

36

VDC

Quiescent current(1

No load VCC=24V

60

100

mA

Alarm current

VCC=24V

150

200

mA

Alarm angle

Relay action point

2.0

7

9.9

°

Relay contact capacity

24V(DC)/250V(AC)

NO

10

A

24V(DC)/ 250V(AC)

NC

5

A

Work temp range

display

-20

+70

sensor

40

+85

Specification parameter

Measuring range

1-axis

-20

+20

°

Resolution

0.1

°

Accuracy (2

RMS

±0.2

°

Zero temp drift

±0.05

±0.08

°/

Size

Display

160*105*32

mm

sensor

41*41*51

mm

IP

Display

IP54

sensor

IP67

Remark 1: Quiescent refers to work current when power supply is DC24Vol and sensor’s angle is less than alarm angle.
Remark 2: Accuracy refers to RMS value between actual angle and measuring angle(≥16 times).

 

V.  EMC (electromagnetic compatibility) Measure And Test

Circumstance phenomenon

Test grade

Unit

Test standard

Performance grade

Static electricity (contact discharge)

±4 (charging voltage)

KV

GB/T 17626.2 / IEC 61000-4-2

C

Static electricity

(air discharge)

±4 (charging voltage)

KV

Fast transient pulses

±2 (charging voltage)

KV

GB/T 17626.4 / IEC 61000-4-4

C

5/50

Tr/Th ns

5 (repeat frequency)

KHz

Surge line-earth)(line-line[positive and negative of power line])①

±2 (open voltage)

KV

GB/T 17626.5 / IEC 61000-4-5

C

1.2/50

Tr/Th us


For Quotation Or Technical Support, Feel Free To Contact Us. We'll Reply You In 24 Hours.

  • *
  • *
  • *
  • *