Single Axis Digital Inclinometer Sensor RS485 Output

Product Short Description

P/N ZCT1360K-LBS-ABUS-77
Axis Single Axis
Accuracy 0.2°
Resolution 0.01°
Power supply DC8~30Vol
Total range 0°~360°
Output RS485
IP Grade IP67
Enquiry

Description

Parameter

How To Order

Download

I. General Description

ZCT1360K-LBS-ABUS-77 is designed and produced by ZC Sensor. Max measuring range is 360 degree, accuracy of 0.2 degree, RS485 output.

 

II. Features 

Great range, high cost performance

Small size, light weight, easy to be integrated

All industrial components, stable performance

Shockproof and anti-vibration

 

III. Application

Angle measurement, zero adjustment

Security control, monitoring and alarm system

 

IV. Technical Parameter room environment25℃))

1. Electrical parameter:

Item

Condition

Min.

Type.

Max.

Unit

Power supply

DC

8

12

30

V

Quiescent  current

No load, horizontal , Vcc=12V

11

mA

2. Performance parameter:

Item

Condition

Min.

type.

Max.

Unit

Total range

0

360

°

Resolution(1

0.01

°

Accuracy (2

±0.2

°

Zero offset

With housing

±0.3

°

Zero temp drift

-40+85(after temp compensation)

±0.003

°/

±0.26

°

-40+85(before temp compensation)

±0.008

°/

±0.5

±0.86

°

Response time (3

No filter

0.1

s

Start up time

1

s

IP grade

With housing

IP67

Work temp range

-40

+85

Remark1: resolution refer to the smallest angle can be detected in the measuring rang.
Remark2: accuracy means the differences between actual value and read out value.
Remark3: response time refer to time required when the output reach to its 85% as for the step change.

 

V. Communication Protocol

Communication protocol is compatible with modbus RTU protocol, with baud rate of 9600bps, without parity, 8 data bits and 1 stop bit.

Register ADD

Data name

Data type

Range

R-W type

Default value

0000H

High byte of X axis angle

User-defined

Measuring range

R

-

0001H

Low byte of X axis angle

User-defined

Measuring range

R

-

0006H

Set/ cancel relative zero

int16U

5A5AH

W

-

0007H

Add of the local sensor

int16U

0000H~ FFFFH

W

-

0008H

Baud rate

int16U

A0A0H~ A2A2H

W

-

R refer to read, W refer to write. 03H can be used to read register, 06H can be used to write register, and 42H can be used to read local sensor address.