High Accuracy Dual Axis Current Output Tilt Sensor ZCT205DL-I1

Product Short Description

P/N ZCT205DL-I1
Axis Dual axis
Accuracy 0.05°
Resolution 0.005°
Power supply DC 12~24Vol
Total range ±5°
Output Current
IP Grade IP68
Enquiry

Description

Parameter

How To Order

Download

I. General Description

ZCT205DL-I1 is researched and produced by Shanghai Zhichuan, it is a high accuracy and high stability current type two-axis inclinometer. The measuring range is ±5 degree, output standard 420mA analog current. It has anti-jamming characteristic, adapt to long distance signal transmission.

 

II. Features

Standard three wire 4-20mA current output

High accuracy

High performance-price ratio

Protection level: IP68

 

III. Application

Engineering mechanism

Angle measuring, level adjust, zero adjust

Security control, monitoring, alarm

Machine arm, dam, construction bridge angle measuring

Aim control, bending control

Original position control, tilt gesture recorder

 

IV. Technical Data

Item

Parameter

Unit

Remark

Measuring range

±5°

degree

Two-axis

Resolution

0.005

degree

Accuracy

0.05

degree

@25±4℃

Sensitivity

1.6

mA/degree

Current output accuracy

0.08

mA

@25±4℃

non-linearity

± 0.5

%FS

@25±4℃

Zero temperature drift

0.01

degree

@-40℃~+85℃

Operating voltage

12~24

V

@DC

Static current

<50

mA

Max load resistance

500

Ω

@Vcc=24V

Zero output current

12

mA

Max output current

<25

mA

Operating temperature

-40 ~  +85

Store temperature

-45 ~  125

Case size

72*72*45

mm

Output wire length

≥1

m

 

Tilt angle and output current (theory value) relevant relationship diagram:

Angle

Theory output current

Angle

Theory output current

Angle

Theory output current

-5

20.000

-1

13.600

3

7.200

-4.5

19.200

-0.5

12.800

3.5

6.400

-4

18.400

0

12.000

4

5.600

-3.5

17.600

0.5

11.200

4.5

4.800

-3

16.800

1

10.400

5

4.000

-2.5

16.000

1.5

9.600

-2

15.200

2

8.800

-1.5

14.400

2.5

8.000

 

Connection definition:

Red: Power +                                  Black: Power

Yellow: X-axis current output                     Blue: Y-axis current output

zc-Connection-definition

Note:

(1) Load resistance and supply voltage need to meet the following formula:

Load resistance ≤(supply voltage6Vvoltage drop of output wire/max output current

For example: supply voltage 12V, output wire 100m, 2*0.14mm2, max output current 20mA. So if supply power is 12V, Load resistance ≤(1260.6/0.02

load resistance should less than or equal to 270Ω.

(2) Shield wire has connected with cathode of power supplier in the side of apparatus. Please hang it in the air when using.

Installation size:

Installation-size

 


For Quotation Or Technical Support, Feel Free To Contact Us. We'll Reply You In 24 Hours.

  • *
  • *
  • *
  • *