ZCTXXXL-XXS-A-7X Series digital inclinometer

Product Short Description

Firm aluminum housing

Built-in 32 – bit microprocessor

Fast operational speed

Non-contact sensing elements , longer use life.

Enquiry

Description

Parameter

How To Order

Download

ZCTXXXL-XXS-A-7X series inclinometer are designed for tower cranes and other construction machinery safety monitoring .these inclinometer use 32 bits high performance MCU, which give double calibration for the linearity,zero-drift.sensitivity deviation of the sensors to make sure the stability and consistency of our sensor.single &dual axis is optional,have got different options for the interface :analog output and digital output can meet different user’requirements .

environmental compatibility:

Parameters

Condition

Min

Typ

Max

Unit

Storing temperature

-30

+85

Working temperature

-30

+85

IP grade

With housing

IP65

   Vibration

Amplitude 2g,Sine wave,10-500Hzfrequency sweep

Surging

GB-T17626.5-2008 Standard,1 grade B

4.other parameters:

Parameters

Condition

Min

Typ

Max

Unit

Housing material

Aluminum housing

Housing size

65*55*27

mm

Weight

No cable

150

g

 


1. Electrical Parameters:

Parameters

Condition

Min

Typ

Max

Unit

Power Supply

DC

11

12

30

V

Quiescent Current

Horizontal Non-load Vcc=12V

20

40

mA

Interface

0~5V、0.5~4.5V Volt;4~20mA Current;RS232;RS485;

2.Performance Parameters

Items

Condition

Min

Typ

Max

Unit

Measuring ranges

Horizontal mounting

±5

±15

°

Resolution(1

Digital output parameters

0.01

0.025

°

Accuracy(2

Digital output parameters

±0.05

±0.1

°

Absolute Zero Point deviation

Digital output parameters

±0.1

±0.2

°

Zero tempt drift

Digital output parameters

±0.65

°

Non-Linearity

Analog output parameter

±0.4

±0.8

%/FS

Sensitivity(3

±15°Range 4-20mA current output

0.5

0.533

0.566

mA/°

±15°Range 0-5V Volt output

156.66

166.66

176.66

mV/°

±15°Range 0.5-4.5VVolt output

125.33

133.33

141.33

mV/°

Load Resistance

Analog volt output Vcc=12V

1M

Ω

Remark:Sensitivity formula=(Volt output range/Current output range)/Measuring range

eg.4-20mA,±15° measuring range.,sensitivity=(20-4)/(15-(-15))=16/30=0.533mA/°.

Sensitivity is different according to different measuring range,,now we take example of 15° ,for other measuring ranges , please calculate according to analog output type and measuring ranges by yourself .

 inclinometer Order information

Optional accessory:4 core M12 Straight hole plugs With inside thread

 

Remark: if the product is RS485 output ,the Part No should be ZCTXXXL-XBS-ABUS-7X

ZCT215L-LAS-A-7X inclinometer   specification

For Quotation Or Technical Support, Feel Free To Contact Us. We'll Reply You In 24 Hours.

  • *
  • *
  • *
  • *