Two-Axis Digital RS485 Tilt Sensor ZCT245AL-485-BUS
Product Short Description
P/N | ZCT245AL-485-BUS |
Axis | Dual axis |
Accuracy | ≤0.5° |
Resolution | 0.1° |
Power supply | DC7~15Vol |
Total range | ±45° |
Output | RS485 |
IP Grade | IP66 |
Description
Parameter
How To Order
Download
I. General Description
ZCT245AL-485-BUS is a two-axis tilt sensor which developed and produced by Shanghai ZC sensor. Its measuring range is ±45 degree. It can communicate with PC via RS485.
II. Features
Small size and light weight.
Be waterproof and dustproof, with aluminium shell.
Stable and reliable performance.
Anti-knock.
Cost effective and ease of integration.
Support +5V or 7-15V power supply (note in order).
III. Applications
Angle measuring, leveling adjustment, zero setting.
Mining machine and petroleum drilling equipment.
Aloft work platform monitoring.
Security control, monitoring, alarm system.
Angular measurement of arm, dam, construction, bridge.
Aligning control, bending control.
IV. Technical Specification(Unless otherwise specified, the following parameters were measured at room temperature 25°C)
|
Parameter |
Condition |
Min. |
Max. |
Unit |
Operating parameter |
Supply voltage |
|
7 |
15 |
V(DC) |
Quiescent current |
|
|
25 |
mA |
|
Working temperature |
|
-40 |
+85 |
℃ |
|
Performance parameter |
Measuring range |
Dual |
-45 |
+45 |
° |
Resolution |
|
|
|
° |
|
Accuracy |
RMS |
|
|
° |
|
Zero temperature drift |
-40~+85℃ |
|
|
°/℃ |
|
Others |
Housing size |
|
|
|
mm |
Cable length |
|
|
|
m |
V. Mounting size and attentions:
1. mounting size
a. Connection definition (Customer provide)
1 |
Schirm / shield |
2 |
7V~12V |
3 |
GND (0 V) |
4 |
RS-485 A |
5 |
RS-485 B |
b. Connection definition (Default)
RED |
7V~12V |
BLACK |
GND (0 V) |
BLUE |
RS-485 A |
YELLOW |
RS-485 B |
c. PCB SIZE and connection definition
Connect definition:
① ――― 7V~12V
② ――― GND
③ ――― RS-485 A
④ ――― RS-485 B
2. Installation attention
Incorrect installment will lead to a big tolerance on the measured angle. Make sure the correct installation of ‘two planes’ and ‘two lines’, please pay attention to the following two points:
①: ‘two planes’ means mounting surface of the sensor should entirely be close to the mounting surface of the measured objects(the mounting surface of the measured objects should be horizontal as possible as it can). Angle is not allowed(eg: angle a in diagram A). Correct installation method refers to diagram B.
②: ‘two lines’ means the axis line should parallel to the axis line of the measured objects. Angle is not allowed(eg: angle b in diagram C). Correct installation method refers to diagram D.
parameter | Condition | Min. | type. | Max. | Unit | |
Operating parameter
|
Supply voltage | 7 | 15 | V(DC) | ||
Quiescent current | Without load | 17 | 25 | mA | ||
Working temperature | -40 | +85 | ℃ | |||
Performance parameter | Measuring range | Dual axis | -45 | +45 | ° | |
Resolution | 0.1 | ° | ||||
Accuracy | RMS | ≤0.5 | ° | |||
Zero temperature drift | -40~+85℃ | ±0.03 | °/℃ | |||
Others
|
Housing size | 41*46*15.2 | mm | |||
Cable length | 0.3 | m |