Low Cost Dual Axis Tilt Switch ZCT245J-LAS-1A-140

Product Short Description

P/N ZCT245J-LAS-1A-140
Axis Dual axis
Accuracy 0.5°
Resolution 0.1°
Power supply DC8~30Vol
Total range +-45°
Output Relay
IP Grade IP65
Enquiry

Description

Parameter

How To Order

Download

I. General Description

ZCT245J-LAS-1A-140 is a dual axis tilt switch researched and produced by Shanghai Zhichuan Electronic Tech Co.Ltd. Measure range ±45 degree both axis. Real time digital angle information; On-off action and trigger delay time; Can be widely used for engineering Machinery.

 

II. Features

Industrial assembly, performance stable and reliable

Shock resistance > 1000g

Wide voltage supply

Reverse polarity protection

Casting aluminum housing

Protection IP65

 

III. Applications

Hydraulic aerial lifts, man lifts

Crane, hoisting machine

Automatic positioning platform

Safety control, monitoring, alarming

 

IV. Technical Parameter ( at room environment 25 centigrade degrees)

Work parameter:

Item

Condition

Min

Typ

Max

Unit

Power supply①

8

12

30

V(DC)

Static operating current②

VCC=12V

30

35

mA

Working temperature

-40

+85

Zero temperature drift

-40~+85℃

±0.03

°/℃

Performance parameter:

Item

Condition

Min

Typ

Max

Unit

Measure range

2-axis

-45

+45

°

 Accuracy

0.5 (RMS)

°

Resolution

0.1

°

Output current③

500

mA

Alarming output voltage

VCC-0.2

V

Alarming delay

2

s

Cable length

1.5

m

Housing size

Aluminum alloy

64*58*35

mm

NOTE 1. DC 12V power supply is recommended, which can reduce the inside device wastage. If supply voltage >30V, maybe cause the device damage or loss of life. Please prevent the over voltage as far as possible.

NOTE 2. Static operating current means the operating current when supply voltage is 12V and no alarm signal output.

NOTE 3. Output current means the current flow of single wire when reach or over the alarm angle.

 

V. User Commands

Function

command

Function description

Default parameter

Set range

Remark

&Z

Set present angle as zero point, relative angle output. Data saved when power off.

No

same as

zero setting

switch

Set present angle as zero angle

&R

Absolute angle output,

Data saved when power off

No

Absolute angle output

#???A

Set alarm angle, it will alarm when the tilt angle ≧alarm angle

001°~450°

Eg. set 3° as alarm angle. Send  command “#030A”,command received and return as“set plane angle alarm angle 03.0”

#???T

Set alarm delay time,

Computing method

Delay time=delay coefficient×0.4,

unit:second

2s

000–100

eg: set alarm delay as 2s,send the command“#005T”,command received and return as“005  set delay time 02.0  second”

Zero set

Set current angle as zero, relative angle output.

No

Same as ‘&Z’

Press set zero button for 2s, ‘set current angle as zero ’is returned when successfully set


  1. I.                    Technical parameterat room environment 25 centigrade degrees):

   Work parameeter:

Item

Condition

Min

Typ

Max

Unit

Power supply①

8

12

30

V(DC)

Static operating current②

VCC=12V

30

35

mA

Working temperature

-40

+85

Zero temperature drift

-40~+85℃

±0.03

°/℃

Performance parameter:

Item

Condition

Min

Typ

Max

Unit

Measure range

2-axis

-45

+45

°

 Accuracy

0.5 (RMS)

°

Resolution

0.1

°

Output current③

500

mA

Alarming output voltage

VCC-0.2

V

Alarming delay

2

s

Cable length

1.5

m

Housing size

Aluminum alloy

64*58*35

mm

NOTE 1. DC 12V power supply is recommended, which can reduce the inside device wastage. If supply voltage >30V, maybe cause the device damage or loss of life. Please prevent the over voltage as far as possible.

NOTE 2. Static operating current means the operating current when supply voltage is 12V and no alarm signal output.

NOTE 3. Output current means the current flow of single wire when reach or over the alarm angle.

 

ZCT245J-LAS-1A-140 date sheet

For Quotation Or Technical Support, Feel Free To Contact Us. We'll Reply You In 24 Hours.

  • *
  • *
  • *
  • *